pastebin

S.M.A.R.T. Monitoring Tools
  1. # smartctl -t long /dev/sda
  2. smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
  3. Home page is http://smartmontools.sourceforge.net/
  4.  
  5. === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
  6. Sending command: "Execute SMART Extended self-test routine immediately
  7. in off-line mode".
  8. Drive command "Execute SMART Extended self-test routine immediately in
  9. off-line mode" successful.
  10. Testing has begun.
  11. Please wait 160 minutes for test to complete.
  12. Test will complete after Tue Jan 12 06:20:32 2020
  13.  
  14. Use smartctl -X to abort test.
  15. ~
  16. # smartctl -a /dev/sda
  17. smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
  18. Home page is http://smartmontools.sourceforge.net/
  19.  
  20. === START OF INFORMATION SECTION ===
  21. Device Model:     WDC WD6401AALS-00J7B1
  22. Serial Number:    WD-WMATV4046792
  23. Firmware Version: 05.00K05
  24. User Capacity:    640,135,028,736 bytes
  25. Device is:        Not in smartctl database [for details use: -P showall]
  26. ATA Version is:   8
  27. ATA Standard is:  Exact ATA specification draft version not indicated
  28. Local Time is:    Tue Jan 12 08:16:35 2010 UTC
  29. SMART support is: Available - device has SMART capability.
  30. SMART support is: Enabled
  31.  
  32. === START OF READ SMART DATA SECTION ===
  33. SMART overall-health self-assessment test result: PASSED
  34.  
  35. General SMART Values:
  36. Offline data collection status:  (0x80) Offline data collection activity
  37.                                         was never started.
  38.                                         Auto Offline Data Collection: Enabled.
  39. Self-test execution status:      (   0) The previous self-test routine completed
  40.                                         without error or no self-test has ever
  41.                                         been run.
  42. Total time to complete Offline
  43. data collection:                 (13200) seconds.
  44. Offline data collection
  45. capabilities:                    (0x7b) SMART execute Offline immediate.
  46.                                         Auto Offline data collection on/off support.
  47.                                         Suspend Offline collection upon new
  48.                                         command.
  49.                                         Offline surface scan supported.
  50.                                         Self-test supported.
  51.                                         Conveyance Self-test supported.
  52.                                         Selective Self-test supported.
  53. SMART capabilities:            (0x0003) Saves SMART data before entering
  54.                                         power-saving mode.
  55.                                         Supports SMART auto save timer.
  56. Error logging capability:        (0x01) Error logging supported.
  57.                                         General Purpose Logging supported.
  58. Short self-test routine
  59. recommended polling time:        (   2) minutes.
  60. Extended self-test routine
  61. recommended polling time:        ( 154) minutes.
  62. Conveyance self-test routine
  63. recommended polling time:        (   5) minutes.
  64. SCT capabilities:              (0x3037) SCT Status supported.
  65.                                         SCT Feature Control supported.
  66.                                         SCT Data Table supported.
  67.  
  68. SMART Attributes Data Structure revision number: 16
  69. Vendor Specific SMART Attributes with Thresholds:
  70. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
  71. UPDATED  WHEN_FAILED RAW_VALUE
  72.   1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail
  73. Always       -       0
  74.   3 Spin_Up_Time            0x0027   250   240   021    Pre-fail
  75. Always       -       7483
  76.   4 Start_Stop_Count        0x0032   100   100   000    Old_age
  77. Always       -       14
  78.   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail
  79. Always       -       0
  80.   7 Seek_Error_Rate         0x002e   200   200   000    Old_age
  81. Always       -       0
  82.   9 Power_On_Hours          0x0032   100   100   000    Old_age
  83. Always       -       5
  84.  10 Spin_Retry_Count        0x0032   100   253   000    Old_age
  85. Always       -       0
  86.  11 Calibration_Retry_Count 0x0032   100   253   000    Old_age
  87. Always       -       0
  88.  12 Power_Cycle_Count       0x0032   100   100   000    Old_age
  89. Always       -       12
  90. 192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age
  91. Always       -       11
  92. 193 Load_Cycle_Count        0x0032   200   200   000    Old_age
  93. Always       -       14
  94. 194 Temperature_Celsius     0x0022   108   107   000    Old_age
  95. Always       -       42
  96. 196 Reallocated_Event_Count 0x0032   200   200   000    Old_age
  97. Always       -       0
  98. 197 Current_Pending_Sector  0x0032   200   200   000    Old_age
  99. Always       -       0
  100. 198 Offline_Uncorrectable   0x0030   100   253   000    Old_age
  101. Offline      -       0
  102. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age
  103. Always       -       0
  104. 200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age
  105. Offline      -       0
  106.  
  107. SMART Error Log Version: 1
  108. No Errors Logged
  109.  
  110. SMART Self-test log structure revision number 1
  111. Num  Test_Description    Status                  Remaining
  112. LifeTime(hours)  LBA_of_first_error
  113. # 1  Extended offline    Completed without error       00%         3         -
  114.  
  115. SMART Selective self-test log data structure revision number 1
  116.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  117.     1        0        0  Not_testing
  118.     2        0        0  Not_testing
  119.     3        0        0  Not_testing
  120.     4        0        0  Not_testing
  121.     5        0        0  Not_testing
  122.     6      0        0  Not_testing
  123.  
  124. Selective self-test flags (0x0):
  125.   After scanning selected spans, do NOT read-scan remainder of disk.
  126. If Selective self-test is pending on power-up, resume after 0 minute delay.
Parsed in 0.022 seconds